pdf,
8,6 MB
ETA_11-0123_englisch_18.04.2023.pdf
protected with flexible cover cap. The anchor head for the passive anchor shall be additionally wrapped with DENSO tape. Retainer plate has to be placed on flexible cover cap. A PE protective cap is set over the anchor head, cover cap and wedge protection disc and is screwed together with front side [...] DENSO tape. Greased strand protrusions are covered with covering tubes. Every covering tube is placed in the wedge protection disc and closed with a plug. A PE protective cap is set on the anchor head, wedge protection disc and strand protrusions and is screwed together with front side of the anchor plate [...] as specified in the Annexes A3, A4 and A8. 1.9 Corrosion protection of exposed steel components Exposed steel components which are not sufficiently covered by concrete (at least 5 cm) or which are not protected by corrosion protection material (e.g. wax) shall be protected against corrosion by one of the[...]